E Encode the test values for video range 16.235/255
F Fill whole screen with black background Ho,vi: 0.0 = left/top, 0.5 = center, 1.0 = right/bottom etc. P ho,vo,ss Position test window and scale it z Run only verify pass on installed calibration curves B blkbright Set the target black brightness in cd/m^2 A rate Rate of blending from neutral to black point. k factor Amount to correct black hue, 0 = none, 1 = full, Default = Automatic a ambient Use viewing condition adjustment for ambient in Lux f Amount of black level accounted for with output offset (default all output offset) G gamma Set the target response curve actual technical gamma Use "-g240" for SMPTE 240M curve (should use -a as well!) Use "-g709" for REC 709 curve (should use -a as well!) g gamma Set the target response curve advertised gamma (Def. b bright Set the target white brightness in cd/m^2
w x,y Set the target white point as chromaticity coordinates T White Black Body locus target, optional target temperaturee in deg. t White Daylight locus target, optional target temperaturee in deg. y n|l Spyder5: Generic Non-Refresh Display q Quality - Very Low, Low, Medium (def), High
u Update previous calibration and (if -o used) ICC profile VideoLUTs O "description" Fast ICC Profile Description string (Default "outfile") m Skip adjustment of the monitor controls R Report on the uncalibrated display then exit r Report on the calibrated display then exit c listno Set communication port from the following list (default 1) dcc Display via n'th ChromeCast (default 1, ? for list) dweb Display via a web server at port (default 8080) d n Choose the display from the following list (default 1)ġ = 'DISPLAY1, at 0, 0, width 1920, height 1080 (Primary Display)'Ģ = 'DISPLAY2, at -1920, 0, width 1920, height 1080' This is what I get: C:\WINDOWS\system32>C:\Users\XXX\Downloads\Argyll_V1.8.3\bin\dispcal -?Īuthor: Graeme W. 23:31:17,223 Waiting for thread ScriptingHost.ConnectionHandler to exit 23:31:17,221 Running application exit handlers 23:25:59,648 Enumerating display devices and communication ports. 23:25:13,387 Enumerating display devices and communication ports.
My Displa圜AL window is the same exact one seen in the linked issue above.
I also went ahead and removed the Datacolor driver and application in case they were somehow interfering.
It took me some time to install properly the Argyll driver but I managed it in the end, still nothing appears. I am using Argyll 1.8.3 (Argyll_V1.8.3_win64_exe.zip) with displa圜AL 3.1.4 but no matter how many times I try to re-install the driver or everything else no monitors (I have 2) nor the Spyder instrument is detected. So I decided to try out Displa圜AL since I’ve always heard good things of it. Before I used the Datacolor app (Spyder 5 Pro) for calibrating, but now on Win10 it returns a bad profile (gray seems more like green). I have just updated from Win 8.1 Pro to Win 10 Pro (64 bit) and I have the same exact issue. I just noticed that I replied to a closed (Not a Bug) issue ( link) instead of a topic, so here I am re-posting it as a topic: